2-Deoxy-2-fluoro-D-glucose (FDG) is a radiolabeled glucose analog used in positron emission tomography (PET) imaging. It is structurally similar to glucose but has a fluorine atom substituted for the 2-hydroxyl group. Because of this substitution, FDG cannot undergo further metabolism like glucose and becomes trapped within cells after being taken up, making it useful for imaging glucose metabolism in tissues.
In PET imaging, FDG is typically administered intravenously to the patient. Once in the body, it is taken up by cells, particularly those that are highly metabolically active, such as cancer cells. The FDG emits positrons, which can be detected by the PET scanner, allowing for the visualization and quantification of metabolic activity in tissues. FDG-PET is commonly used in oncology for cancer staging, treatment planning, and monitoring, as well as in cardiology and neurology for assessing various conditions.
Description of 2-Deoxy-2-fluoro-D-glucose from Wuhan Fortuna Chemical Co.,Ltd
Basic Information of 2-Deoxy-2-fluoro-D-glucose | |
Product Name | 2-Deoxy-2-fluoro-D-glucose |
CAS NO. | 29702-43-0 |
Apperance | White solid |
Assay | 98% |
Pacakge | 1g/Foil Bag,25kg/Drum/Box |
MOQ | 1g |
Storage | Cool and dry place |
Shelf Life | 2 Years |
Brand | Fortunachem |
Specifications(COA) of Good quality Biochemical 2-Deoxy-2-fluoro-D-glucose CAS 29702-43-0 with steady supply
Items | Specifications | Results |
Appearance | White Solid | Conforms |
Assay | ≥98% | 98% |
Conclusion | QUALIFIED. |
Introduction of 2-Deoxy-2-fluoro-D-glucose.
2-Deoxy-2-fluoro-D-glucose (FDG) is a radiolabeled glucose analog used in positron emission tomography (PET) imaging. It is structurally similar to glucose but has a fluorine atom substituted for the 2-hydroxyl group. Because of this substitution, FDG cannot undergo further metabolism like glucose and becomes trapped within cells after being taken up, making it useful for imaging glucose metabolism in tissues.
In PET imaging, FDG is typically administered intravenously to the patient. Once in the body, it is taken up by cells, particularly those that are highly metabolically active, such as cancer cells. The FDG emits positrons, which can be detected by the PET scanner, allowing for the visualization and quantification of metabolic activity in tissues. FDG-PET is commonly used in oncology for cancer staging, treatment planning, and monitoring, as well as in cardiology and neurology for assessing various conditions.
Application of 2-Deoxy-2-fluoro-D-glucose.
The application of 2-Deoxy-2-fluoro-D-glucose (FDG) primarily lies in medical imaging, specifically in positron emission tomography (PET). Here are some key applications:
1. Oncology: FDG-PET is extensively used in oncology for various purposes:
- Cancer diagnosis: FDG-PET can help detect and diagnose various types of cancers, including lung cancer, breast cancer, colorectal cancer, lymphoma, and more.
- Staging: It assists in determining the extent and spread of cancer within the body, aiding in cancer staging.
- Treatment planning: FDG-PET helps in planning cancer treatment strategies by identifying the most active areas of tumor metabolism.
- Treatment response assessment: It is used to monitor the response of tumors to therapy, helping physicians evaluate the effectiveness of treatments such as chemotherapy, radiation therapy, and targeted therapy.
- Detection of recurrence: FDG-PET is valuable in detecting cancer recurrence after treatment.
2. Neurology: FDG-PET has applications in neurology for:
- Brain imaging: It is used to evaluate brain function, detect abnormalities related to neurodegenerative diseases like Alzheimer's disease, Parkinson's disease, and epilepsy, and aid in the diagnosis of dementia.
- Epilepsy localization: FDG-PET can help localize the regions of the brain responsible for seizures in patients with epilepsy, assisting in surgical planning.
3. Cardiology: In cardiology, FDG-PET is employed for:
- Assessment of myocardial viability: It helps determine viable myocardium (heart muscle tissue) in patients with coronary artery disease or heart failure, aiding in treatment decisions such as revascularization procedures.
- Detection of cardiac sarcoidosis: FDG-PET can identify inflammation in the heart associated with sarcoidosis, an autoimmune disease.
4. Inflammation and Infection Imaging: FDG-PET can be used to detect sites of inflammation and infection in various parts of the body, helping diagnose conditions such as vasculitis, osteomyelitis, and infectious diseases.
Overall, FDG-PET imaging plays a crucial role in diagnosing diseases, guiding treatment decisions, monitoring treatment response, and improving patient outcomes across a wide range of medical specialties.
FAQ From Wuhan Fortuna Chemical Co.,Ltd | |
Q | Can I get a sample for free ? |
A | For small QTY and low value product, we can provide sample for free exclude shipping cost. For high value sample, we will charge the basic sample cost, but we can refund all the cost if customers place order after sample test. |
Q | How to confirm the product quality before placing orders ? |
A | Most of our products confirm to international standards like USP/EP/BP/JP/CP. We will provide COA/TDS/MSDS for customers to confirm the specification before placing order. |
Q | What is the payment you accept? |
A | For small and low value order, we accept CreditCard, MaterCard,VISA,Western Union and T/T.For large order, we can do T/T and L/C. Any pay on delivery or pay-after are not available for us. |
Q | What is your shipment way ? |
A | For less than 100kg gross weight order will ship with courier like FedEx or UPS, we support customers to place courier orders remotely by their account, we will package the goods well and wait for pick up.For more than 100kg goods, we will transport by Air or Sea according to customers' requirement. |
Q | How long is your after-sales service? |
A | We accept customer’s quality complaint in three month after customer received the goods. We provide tech.support for all-life if customer place order from our company. |
Q | How do you treat quality complaint ? |
A | We support customer to provide our products to any rightful third party testing organization to test our products according to the COA specification, if the test result is confirm with COA, we will take all the loss for customers. |
Wuhan Fortuna Chemical Co.,Ltd established in 2006, is a big integrative chemical enterprise being engaged in Pharmaceutical and Intermediates, Food and Feed additives, Fine chemicals,Biochemical and Reagent, which is the members of Hubei E-commerce Chamber.
Our company has professional persons who major in chemical R&D and sicentific management, supply fine chemical products with high quality and close service, also supply custom-tailored products according to our clients' requirement.
We have a positive and self-motivated management work team with a common philosophy, caring and commitment through teamwork, our team strive to achieve success in delighting our clients and ourselves.
Since Wuhan Fortuna Chemical Co., Ltd founded, we continuously innovate our products and improve our service, sales network. Hence, we initiate the first sale mode on net in China, which is the retail trade of small package bring along wholesale of diversified management modes. Our products are exported widely to South Korea, Vietnam, Australia, Europe and South America, highly recommended by our clients.We insist on the management creed “Market is our compass, Quality is our life, Credit is our soul”. Clients’ trust is our forward power, their satisfaction is our struggling goal.
Wuhan Fortuna Chemical Co.,Ltd is a professional manufacturer which provide 2-Deoxy-2-fluoro-D-glucose with good quality and best price, welcome to contact us to get COA/TDS/MSDS of 2-Deoxy-2-fluoro-D-glucose.
Fortunachem Provides Not Only Professional Chemical Products But Also Professional Help